Variable Speed Drives (VSD) for Electric Motors – Sydney

A variable speed drive (VSD), also called a variable frequency drive (VFD) or inverter, controls the speed and torque of an electric motor. By matching motor output to what your process actually needs, a VSD cuts energy use, reduces mechanical wear and gives you smooth, precise control.

MNP Electrical supplies a range of single-phase and three-phase VSDs from trusted brands including Control Techniques and WEG, backed by the electrical knowledge of a Sydney motor repair specialist. Browse the range below or contact us and we will help you choose the right drive.

Shop VSDs Request a Quote

WEG CFW500 variable speed drive for single and three phase motors, supplied in Sydney by MNP Electrical

Benefits of a variable speed drive

  • Lower energy costs – running a pump or fan slightly slower can reduce power consumption significantly.
  • Soft start and stop – reduces inrush current and mechanical shock on motors, belts, couplings and gearboxes.
  • Longer equipment life – less stress means fewer breakdowns and lower maintenance costs.
  • Precise process control – adjust speed to suit flow, pressure, temperature or production rate.
  • Motor protection – built-in protection against overload, over-current, over-voltage and phase faults.
  • Single-phase to three-phase – many drives let you run a three-phase motor from a single-phase supply.

Our variable speed drive range

We supply compact drives for small and medium motors, including:

  • Control Techniques S100 – compact, easy-to-commission drives available in 100/120V and 200/240V single phase and 200/240V three phase.
  • WEG CFW500 (see the WEG website for full specifications) – versatile, feature-rich drives with flexible control and communication options.
  • Ratings from 0.18 kW and up – sized to suit small motors, fans, pumps, conveyors and machinery.
  • EMC filter options – choose C1 (residential and light commercial) or C3 (industrial) to suit your installation environment.

Prices start from $300 and are listed on each product page. Need a larger drive or a specific model? Contact us and we will source it.

VSD

How to choose the right VSD

  • Motor power and current – match the drive to the motor’s kW and full-load amps.
  • Supply voltage and phase – confirm whether you have a single-phase or three-phase supply.
  • Application – pumps and fans are variable torque; conveyors, mixers and crushers usually need constant torque.
  • EMC environment – select C1 or C3 depending on where the drive is installed.
  • Controls and communications – consider start/stop inputs, speed reference, relays and fieldbus options.

Send us your motor nameplate and a few application details and we will recommend the correct model.

Typical applications

Pumps and pressure-boosting systems, fans and blowers, conveyors, mixers, compressors, packaging machinery, workshop machinery, HVAC and ventilation, and gearbox-driven equipment.

Complete drive solutions from one supplier

As well as variable speed drives, MNP Electrical supplies electric motors and gearboxes and offers industrial gearbox repair, and repairs motors, pumps, generators and gearboxes. We can supply a motor, gearbox and VSD that work properly together, and help if your existing motor needs a rewind or service before it is paired with a new drive.

Why buy from MNP Electrical

  • Local Sydney expertise – more than 15 years of experience with motors and drives.
  • Genuine brands – Control Techniques and WEG drives you can trust.
  • Honest advice – we recommend what suits your motor and budget, not just what is in stock.
  • Simple online ordering – add standard drives to your cart or call us for a custom quote.
  • Ongoing support – questions about selection or setup? Our team is happy to help.

Frequently asked questions

What is the difference between a VSD, VFD and inverter?

They are different names for the same device: it varies the frequency and voltage supplied to an AC motor to control its speed.

Can I run a three-phase motor on a single-phase supply?

Yes, with a single-phase input VSD that outputs three phase. The drive must be sized correctly for the motor, and a larger drive rating is often needed.

Will a VSD save me money?

On variable-load equipment such as pumps and fans, a VSD can deliver significant energy savings. It also reduces wear through soft starting.

What size VSD do I need?

Match the drive’s current rating to your motor’s full-load current, not just the kW. If you are unsure, send us your motor nameplate and we will confirm.

What does C1 or C3 mean?

These are EMC filter categories. C1 suits residential and light commercial environments, while C3 suits industrial environments.

VSD or star delta starter – which do I need?

A star delta starter reduces starting current by starting the motor in star and switching to delta, but the motor still runs at one fixed speed. A VSD gives you a soft start plus full speed control and energy savings, which makes it the better choice for pumps, fans and conveyors that don’t need to run flat out.

Do I still need a thermal overload relay with a VSD?

In most single-motor installations the drive’s built-in electronic motor overload protection does the job of a separate thermal overload relay, once the motor’s full-load current is set in the drive. Your electrician will confirm what your installation requires.

How is a 3 phase motor connected to a VSD?

The 3 phase motor connection (star or delta) must match the drive’s output voltage shown on the motor nameplate. For example, a 230/400V motor is connected in star on a 400V three-phase drive, and in delta on a single-phase input drive with a 230V three-phase output. Wiring should always be done by a licensed electrician.

Do you offer setup advice?

Yes. We can help with drive selection and answer questions about wiring and basic parameter settings.

Ready for a variable speed drive in Sydney?

Shop our variable speed drive range online or call MNP Electrical for expert help choosing the right VSD.

Shop VSDs Request a Quote

0
YOUR CART
  • No products in the cart.